
CytoPure™ Transfection Reagent 
- First reagent to biodegrade upon delivery into cell
- Superior transfection efficiency in a broad range of cell lines
- Effective in presence or absence of serum
- Low toxicity
- Easy-to-use and supplied with an optimized
protocol
|
|
|
New Biodegradable Transfection Reagent

CytoPure™ is a revolutionary new reagent for transfection of plasmid
DNA into a broad range of mammalian and insect cells. CytoPure™ is
the first transfection reagent on the market proven to biodegrade into
small, non-toxic molecules upon entry into the cell. Derived from a proprietary
cationic polymer, the biodegradable nature of CytoPure™ increases
the transgene expression and reduces the cellular cytotoxicity typically
caused by large cationic polymers. The increased viability of transfected
cells makes CytoPure™ the optimal choice for researchers trying
to establish stable cell lines.
Biodegradation Mode of Action 
Illustrated in Figure 1, the cationic polymers
of CytoPure™ function
by associating with negatively charged nucleic acid molecules to form a polyplex
having a net positive charge. During endocytosis, the cationic polymers within
the polyplex protect the nucleic acid and later facilitate release through
the nuclear membrane. While other cationic polymers tend to accumulate in the
cell nucleus resulting in high toxicity, CytoPure™ polymers biodegrade
into small, non-toxic molecules which promote increased cell survival and overall
cell health.
 |
Figure 1
CytoPure™ biodegradation mode of action. 1. Attachment
and endocytosis; 2. Endosome escape; 3. Nuclear localization;
4. CytoPure™ degradation and DNA release |
 |
 |
Figure
2
Analysis of CytoPure™ polymer biodegradation
into small, non-toxic particles.
A. GFP tracking of
reagent biodegradation in 293 cells post-transfection
B.
GPC analysis of molecular weight decrease of CytoPure™ polymer
over time |
 |
Figure
3
Viability of 293 cells 24 hours post-transfection measured by MTT assay |
 |
Figure
4
HUVEC cell condition post transfection with CytoPure™:DNA ratio of 14:1 |
 |
Figure
5
Visualization of eGFP in HUVEC post transfection with CytoPure™:DNA ratio of
14:1, exhibiting close to 50% transfection efficiency |
Common
Cell Lines |
|
Transfection Efficiency GFP Positive
Cells |
Cytotoxicity |
293 |
Human embryonal kidney |
>95% |
<5% |
293 T |
Human embryonal kidney (SV40T antigen) |
>95% |
<5% |
HT 1080 |
Human fibrosarcoma |
>85% |
5-10% |
Hela |
Human cervix adenocarcinoma |
>70% |
5-10% |
HepG2 |
Human heptocyte carcinoma |
20-30% |
<5% |
Cos7 |
Monkey kidney fibroblast cell |
>85% |
<5% |
208F |
Murine fibroblast cells |
20-30% |
<5% |
Caco-2 |
Human colorectal epithelial adenocarcinoma |
20-30% |
<5% |
1471.1 |
Murine brast adeno carcinoma |
>95% |
<5% |
NIH3T3 |
Murine fibroblast cells |
>60% |
<5% |
A549 |
Lung cancer cell |
>60% |
<5% |
MDA-MB-436 |
Human breast cancer cells |
>60% |
<5% |
Sf9 |
Insect cells |
>70% |
<5% |
Calu 6 |
Lung cancer cell |
>50% |
<5% |
|
Primary Adherent Cells |
HUVEC |
Human umbilica vascular endothelial
cells |
35-50% |
10-15% |
Cortex neuron |
Rat cortex neurons |
10% |
0% |
Hippocampus neuron |
Rat hippocampus neurons |
9% |
0% |
Cerebellar granule neuron |
Rat cerebellar granule neurons |
10% |
0% |
Rat myocardium cell |
Rat myocardium cells |
9% |
0% |
|
Precursor Cells |
NT2 |
Human Neuron cell |
5% |
5-10% |
 |
Suspension Cells |
K563 |
Human chronic myelogenous leukemia |
15-20% |
5-10% |
Table 1
Typical transfection efficiencies and cell cytotoxicity values obtained in various
cell lines using CytoPure™
Available in Two Formulations for Optimization

CytoPure™ is available in two formulations: CytoPure™ -cmn
is suited for a broad range of mammalian cells such as 293T, Cos 7,
and HeLa. The second formulation is CytoPure™ - huv, which
has been specifically designed for HUVEC and other primary and difficult
to transfect cells. CytoPure™ reagents are easy to use
and are suitable for both first time users and those experienced in
transfection.
Stability & Storage: CytoPure™ is
stable for 1 year when stored at 4°C
Cat. # |
Description |
Size |
Number of
transfections
(12 - well plate) |
| 7000-014 |
CytoPure™ - cmn transfection
reagent |
0.5 ml |
125-250 |
| 7000-024 |
CytoPure™ - cmn transfection
reagent |
1.0 ml |
250-500 |
| 7000-034 |
CytoPure™ - cmn transfection
reagent |
5x1.0ml |
1,250-2,500 |
| |
|
|
|
| 7000-114 |
CytoPure™ - huv transfection
reagent |
0.5 ml |
125-250 |
| 7000-124 |
CytoPure™ - huv transfection
reagent |
1.0 ml |
250-500 |
| 7000-134 |
CytoPure™ - huv transfection
reagent |
5x1.0ml |
1,250-2,500 |

|